Machine Support
**Every new argon filling machine (not including In-Line Testers) will include the push button calibration boards as standard equipment.**
ASL

- Air Space Laser that determines dimensions of glass and air space
- Measures glass deflection in sealed glass units
- Quick and accurate measurements taken from one side of the IG unit
- Scales include metric, 1/8", decimal inch, and glass thickness
- Complete with carrying case and belt holder
- Designed and manufactured in North America, serviced worldwide
ILT

- In-Line Tester that tests fill percentage during the manufacturing process
- Includes FDR conductivity sensor (ILT-C) or oxygen sensor (ILT-O)
- Optional printer (ILT-CP) available for documentation
- Circulates gas in cavity for rapid, accurate testing
- Closed loop system utilizes large gas sample
- ILT-C and ILT-CP displays show percentage of argon
- ILT-O displays show percentage of oxygen
- Uses existing gas filling holes
- Single-line
- Flow Rate = 8 Liters per minute
- Designed and manufactured in North America, serviced worldwide
RSGa

- Single-line gas filler
- Two-hole filling; vertical fill or tilted > 10 degrees
- Includes FDR gas sensor and computer control
- Gas sensor meter for visual display of filling process
- Gas flow shuts off automatically when IG unit is full
- Flow Rate = 6 Liters per minute
- *Time to fill = 140 seconds
- Complete with filling lance, sniffler, bottle regulator, and hoses
- Designed and manufactured in North America, serviced worldwide
RSGd

- Multiple-line gas filler
- Two-hole filling; vertical fill or tilted > 10 degrees
- Includes FDR gas sensor and computer control
- Gas sensor meter for visual display of filling process
- Gas flow shuts off automatically when IG unit is full
- Upgradeable from 1 to 4 output lines
- Flow Rate = 9-18 Liters per minute (dependant on exhaust hole size)
- *Time to fill = (2-hole filling) 71 seconds; (1-hole filling) 110 seconds
- Complete with filling lance, sniffler, bottle regulator, and hoses
- Designed and manufactured in North America, serviced worldwide
RSGe

- Single-line gas filler
- One-hole filling capability
- Two-hole filling; vertical fill or tilted > 10 degrees
- Includes FDR gas sensor and computer control
- Gas sensor meter for visual display of filling process
- Gas flow shuts off automatically when IG unit is full
- Flow Rate = 15-28 Liters per minute (dependant on exhaust hole size)
- *Time to fill = (2 hole filling) 71 seconds; (1 hole filling) 110 seconds
- Complete with filling lance, sniffler, bottle regulator, and hoses
- Designed and manufactured in North America, serviced worldwide
RSGh

- Multiple-line gas filler
- One-hole filling capability
- Two-hole filling; vertical fill or tilted > 10 degrees
- Includes FDR gas sensor and computer control
- Gas sensor meter for visual display of filling process
- Gas flow shuts off automatically when IG unit is full
- Flow Rate = 15-28 Liters per minute (dependant on exhaust hole size)
- *Time to fill = (2 hole filling) 71 seconds; ( 1 hole filling) 110 seconds
- Complete with filling lances, snifflers, bottle regulator, and hoses
- Designed and manufactured in North America, serviced worldwide
RSGi

- Two-line gas filler
- Two-hole filling; vertical fill or tilted > 10 degrees
- Includes FDR gas sensor and computer control
- Gas sensor meter for visual display of filling process
- Gas flow shuts off automatically when IG unit is full
- Flow Rate = 6 Liters per minute
- *Time to fill = 140 seconds
- Optional krypton sensors and recovery interface (RSGkr)
- Complete with filling lance, sniffler, bottle regulator, and hoses
- Designed and manufactured in North America, serviced worldwide
RSGz

- Single-line, high speed gas filler
- Two or Three hole filling option; vertical fill or tilted > 10 degrees
- Includes FDR gas and pressure sensors with computer control
- Meters for visual display of filling process
- Gas flow shuts off automatically when IG unit is full
- Flow Rate = (RSGz-40) 20-45 Liters per minute; (RSGz-90) 20-90 Liters per minute; (RSGz-175) 20-175 Liters per minute (dependant on exhaust hole size)
- *Time to fill = (RSGz-40) 61 seconds; (RSGz-90) 38 seconds; (RSGz-175) 14 seconds
- Complete with filling lance, sniffler, bottle regulator, and hoses
- Designed and manufactured in North America, serviced worldwide
*Unit used for time to fill test: Height: 48" - 1220mm; Width: 24" - 610mm; Volume: 767 cubic inches - .44 cubic feet - 12.6 liters; Area: 8 square feet - .74 square meters; Spacer: 21/32" - .665" - 17mm